3. Align the combination HW1490 Support Bars and Burglary
Module PCB with the holes located in HW1492 Right Side Plate
and the HW1491 Left Side Plate. Secure using four thumbscrews
(item #4).
4. Orient the Burglary Module above the motherboard with its ter-
minals towards the left side. On the right side of the Burglary
Module is a polarized 12 pin female connector "J2"; insert J2 into
the male 12 pin connector "J8" on the motherboard. Using the
four 6-32 screws, mount the Burglary Module to the two HW1490
Support Bars.
5. Route the wires from the Burglary Module to the left and down
the side of the enclosure, as shown in the following image. The
red and black non-power limited battery flying leads are double-
insulated to meet NEC requirements and do NOT need to be se-
cured at least ¼" away from power-limited wires inside the enclo-
sure. Several tie wrap holes in the HW1490 Support Bar are
available to secure wires if needed.
TERMINAL DESCRIPTIONS
Maximum Burglary alarm and standby current can not exceed cal-
culated maximum available Power Supply Current or Available Bat-
tery Standby Current, whichever is less. Typically, this is deter-
mined by the Available Battery Standby Current. Both must be cal-
culated using detailed spreadsheets to be created and provided for
review by the authority having jurisdiction.
3
EXPLODED VIEW OF GEMC-BM / PS BURG MODULE.
SEE TABLE BELOW FOR NUMBER DESCRIPTIONS
Item Part # Description QTY
1 HW1688 Enclosure base 1
2 PCB Burg Burg PCB 1
3 HW1490 Support Bar 2
4 SC628 Thumbscrew 4
5 WA107 #6 External Tooth Star Washer 4
6 SC270 Screw 6-32 x .25 with washer 4
ROUTE GEMC-BM / PS BATTERY WIRES
Note: There are no integral burglary zones. Burglary zones re-
quire either GEMC-EZM's wired to the Burg Bus, SLC modules
connected to the motherboard, or a wireless receiver (GEMC-
RECV) wired to the Fire bus (may be wired to the burg bus on a
burg-only system).
BELL ("Bell Output")
Terminal 1: Burg (+)
Terminal 2: Burg (–)
Supervised for open; use only one bell for proper supervision.
Do not wire to any Fire devices. Power limited output.
Requires 2.2K EOLR.
AUX PWR
Terminal 3: Aux Power (+)
Terminal 4: Aux Power (–)
Separate Burglary Auxiliary Power for Burglary peripherals such
as PIR's. Power limited output. Do not wire to any Fire devices.
PGM1, 2
Terminal 5, 6: PGM1 (–), PGM2 (–)
Programmable by zone, active low open collector outputs. Do
not wire to any Fire devices.
BURG BUS ("Remote Bus")
Terminal 7: Remote (+)
Terminal 8: Remote (–)
Terminal 9: Remote GRN
Terminal 10: Remote YEL
Do not wire to any Fire devices.
Peripherals: GEMC-BK1 (at least one required), GEMC-EZM,
GEMC-OUT8, GEMC-RM3008, GEM-ACM1D and GEMC-
RECV. Separate Burglary Bus supports all existing Gemini C-
Series Burglary peripherals and a maximum of 15 keypads
(using separate UL603 listed power supply, model GEMC-
12V2APS-CF or GEMC-12V2APS-R).